installation instructions LV08P

installation instructions:

LV08-pos

.

.

.

.

.

.

.

.

.

.

.

.

 

 

 

LV08-neg.

.

.

.

.

.

.

.

.

.

.

.

.

 

Anzeige Sicherung defekt

LV08-sich.

.

.

.

.

.

.

.

.

.

.

.

Description:
The LV08P has 8 inputs and 8 outputs. If a voltage is applied to the input, then the
corresponding output is activated and the connected magnet is energized. Both are indicated by LEDs.
To drive an input only a few Miliampere are needed, the output can deliver up to 2A.
Inputs and outputs are galvanically isolated via optocouplers. The module is equipped with a main fuse
16A MT hedged. If a short circuit or an overload occurs on the channel, the fuse switches off the channel,
it then flows only a small holding current and the output LED is off. Is the short circuit or the
Overload off, the channel automatically switches back on.

installation:
The assembly is designed for dry rooms only, it should be perpendicular to the outputs if possible
to be mounted below. During operation, the assembly heats up, so ensure adequate ventilation. The
resettable fuses are temperature dependent. The assembly heats up because of an inappropriate
Installed, so the fuses switch earlier. The module is designed for a continuous current of 1.5A during continuous operation
designed for all channels. At 2A on all channels, the channels will turn off after a few minutes. At 3A on
4 channels is switched off after typically 45 seconds. In order not to endanger the module in the event of a short circuit, must
the power supply the current to max. Limit 40A. The module is optional with other fuses and
Switching transistors available, so even higher currents can be processed.